Duplicating Media from IBM ProtecTIER
When data is saved to the IBM ProtecTIER (TS7650, T7620, TS7610), the data is not compacted. This can cause extra media to be used when duplicating the volumes to other types of tape.
To ensure that data is compacted on the output or duplicate media, users need to specify COMPACT(*YES)
or COMPACT(*DEV)
on the DUPMEDBRM
command.
When planning on changing the command default, refer to this URL
Reference this Use Compaction on Tapes Duplicated with DUPMEDBRM for more information on the COMPACT parameter