Control Group Exit Program Enhancements

Enhancements to the control group exit program

  1. The exit program now has the ability to run at the end of the control group (in addition to, or instead of after each item backed up).

  2. New information in the user space header to the exit program includes:

    Completion Type

B = For a Backup Item  C= For the Control Group

Completion Status 

N = Completed Normally  E = Completed with Errors  F = FAILED

Completion Error Message

Error Message is only populated if completion status is ‘E’ or ‘F’).

Interface updated

The interface has been updated to reflect the functionality.

BKUI0200–Backup Item Entry Information

The following table defines the enhanced format for backup item entry information. This format is only valid for backup control groups.

Offset

Type

Field

Dec

Hex

0

0

Binary(4)

Number of entries

4

4

Binary(4)

Length of entry information

8

8

Binary(4)

Starting message key

12

C

Binary(4)

Ending message key

16

10

Binary(4)

Offset to first entry

20

14

Char(1)

Completion type

21

15

Char(1)

Completion status

22

16

Char(7)

Completion error message

The following fields repeat for each entry.

 

 

Binary(4)

Offset to next entry

 

 

Binary(4)

Length of entry

 

 

Binary(4)

Offset to command

 

 

Binary(4)

Length of Command

 

 

Binary(4)

Sequence

 

 

Char(10)

Backup item

 

 

Char(4)

Backup item type

 

 

Char(10)

Backup item auxiliary storage pool device

 

 

Char(*)

Command

 

Using the enhanced functionality

 

Backup item auxiliary storage pool device

The auxiliary storage pool device for the backup item. See the help on the Edit Backup Control Group Entries display for additional information and possible values returned in the field. This field may be blank for entries which do not support this field.

Backup item

The backup item just processed. See the help on the Edit Backup Control Group Entries display for additional information and possible values returned in the field.

Backup item type

The backup item type just processed. See the help on the Edit Backup Control Group Entries display for additional information and possible values returned in the field.

Command

The command just processed for *EXIT backup items. The command is returned in UNICODE CCSID 1200.

Completion error message

This is the error message for a backup item or control group that completes processing with errors or fails. If completion status is, N, this field will be blank.

Completion status

The completion status for the backup item or control group is designated with:

N

Normal completion

E

Completed with errors

F

Failed to complete

Completion type

Indicates the type of completion information:

B

Backup item

C

Backup control group

Ending message key

This is the ending message key for receiving messages generated by the processed entries. The exit program can receive messages for processed entries beginning with the starting message key through the ending message key.

Length of entry information

The length of the control group entry information.

Length of entry

The length of the current entry. This length does not include the length of the command for *EXIT entries.

Length of command

The length in bytes of the command data associated with an *EXIT backup item. The length is 0 if the backup item is not *EXIT.

Number of entries

Most control group entries are processed individually. Some entries may be grouped if they have similar auxiliary storage pools, activity, object detail, and save-while-active attributes. This field indicates the number of entries in the group.

Offset to command

The offset of the command data associated with an *EXIT backup item. The offset is 0 if the backup item is not *EXIT. This offset is relative to the start of the backup item information.

Offset to first entry

The offset to the first entry in the control group entry information. This offset is relative to the start of the control group entry information.

Offset to next entry

The offset to the next entry in the control group entry information. The offset is 0 if this is the last entry. This offset is relative to the start of the control group entry information.

Sequence

The sequence number of the control group entry. See the help on the Edit Backup Control Group Entries display for additional information and possible values returned in the field.

Starting message key

This is the starting message key for receiving messages generated by the processed entries. The exit program can receive messages for processed entries beginning with the starting message key through the ending message key.

Using the Old World Call

To set the exit program to use format BKUI0200 which runs the exit program only at the end of the control group run one of the following commands:

In 7.3 and 7.4 run the following commands:

CALL QBRM/Q1AOLD PARM('SETUPFUN  ' '*SET    ' 'Q1ABUEPFM2 ' '*JOB')    - set up for current job only

CALL QBRM/Q1AOLD PARM('SETUPFUN  ' '*SET    ' 'Q1ABUEPFM2' '*SYS')    - set up to affect all jobs

In 5770-BR2 7.4, 5770-BR2 7.5, and 5770-BR1 7.5 run the following command:

SETFCNBRM ACTION(*ADD) FUNCTION(BUEPFM2) SCOPE(*SYS)

The SCOPE parameter also supports *JOB to only affect the current signed on job. 

To set the exit program to use format *BOTH which runs the exit program after each backup item and again at the end of the control group run one of the following commands:

In 5770-BR1 7.3 and 7.4 run the following commands:

CALL QBRM/Q1AOLD PARM('SETUPFUN  ' '*SET    ' 'Q1ABUEPALL ' '*JOB')    - set up for current job only

CALL QBRM/Q1AOLD PARM('SETUPFUN  ' '*SET    ' 'Q1ABUEPALL' '*SYS')    - set up to affect all jobs

In 5770-BR2 7.4, 5770-BR2 7.5, and 5770-BR1 7.5 run the following command:

SETFCNBRM ACTION(*ADD) FUNCTION(BUEPALL) SCOPE(*SYS)

The SCOPE parameter also supports *JOB to only affect the current signed on job. 

 To set the exit program back to the default format BKUI0100 which runs the exit program after each backup item run one of the following commands:

In 5770-BR1 7.3 and 7.4 run the following commands:

CALL QBRM/Q1AOLD PARM('SETUPFUN  ' '*SET    ' 'Q1ABUEPFM1' '*JOB')    - set up for current job only

CALL QBRM/Q1AOLD PARM('SETUPFUN  ' '*SET    ' 'Q1ABUEPFM1' '*SYS')    - set up to affect all jobs

In 5770-BR2 7.4, 5770-BR2 7.5, and 5770-BR1 7.5 run the following command:

SETFCNBRM ACTION(*ADD) FUNCTION(BUEPFM1) SCOPE(*SYS)

The SCOPE parameter also supports *JOB to only affect the current signed on job. 

To remove:

These ALL remove the Data Area at the job level, no need to run it for each function name.

In 5770-BR1 7.3 and 7.4 run the following commands:

CALL QBRM/Q1AOLD PARM('SETUPFUN ' '*REMOVE ' 'Q1ABUEPFM1' '*JOB') - remove for current job only

or CALL QBRM/Q1AOLD PARM('SETUPFUN ' '*REMOVE ' 'Q1ABUEPFM2' '*JOB') - remove for current job only

or CALL QBRM/Q1AOLD PARM('SETUPFUN ' '*REMOVE ' 'Q1ABUEPALL' '*JOB') - remove for current job only

These ALL remove the Data Area for all jobs, no need to run it for each function name.

CALL QBRM/Q1AOLD PARM('SETUPFUN ' '*REMOVE ' 'Q1ABUEPFM1' '*SYS') - remove for all jobs

or CALL QBRM/Q1AOLD PARM('SETUPFUN ' '*REMOVE ' 'Q1ABUEPFM2' '*SYS') - remove for all jobs

or CALL QBRM/Q1AOLD PARM('SETUPFUN ' '*REMOVE ' 'Q1ABUEPALL' '*SYS') - remove for all jobs

In 5770-BR2 7.4, 5770-BR2 7.5, and 5770-BR1 7.5 run one of the following command:

SETFCNBRM ACTION(*REMOVE) FUNCTION(BUEPFM1) SCOPE(*SYS)

SETFCNBRM ACTION(*REMOVE) FUNCTION(BUEPFM2) SCOPE(*SYS)

SETFCNBRM ACTION(*REMOVE) FUNCTION(BUEPALL) SCOPE(*SYS)

To check what is setup:

In 5770-BR1 7.3 and 7.4 run the following:

These ALL return the same info, no need to run it for each function name.

CALL QBRM/Q1AOLD PARM('SETUPFUN' '*DISPLAY' 'Q1ABUEPFM1' )

or CALL QBRM/Q1AOLD PARM('SETUPFUN' '*DISPLAY' 'Q1BUEPFM2' )

or CALL QBRM/Q1AOLD PARM('SETUPFUN' '*DISPLAY' 'Q1ABUEPALL' )

In 5770-BR2 7.4, 5770-BR2 7.5, and 5770-BR1 7.5 to display what the current setting is run the following command:

DSPFCNBRM FUNCTION(*ALL)  then press F10 to see the detailed results.