Synchronizing System Times - Q1ASYNTIM
Learn how to synchronize systems
When PTFs SI38733 for V5R4M0 or SI38739 for IBM i 6.1 or their superseding PTFs are loaded and applied, BRMS will no longer support the option 8 "Set time" on the network panel (WRKPCYBRM TYPE(*SYS)
Option 4). Those still wishing to use the function can create the following data area:
CRTDTAARA DTAARA(QUSRBRM/Q1ASYNTIM) TYPE(*CHAR) LEN(1)
Once this data areas exists, WRKPCYBRM TYPE(*SYS)
Option 4 Option 8 will synchronize the time on the target system to the current system's time.