Adding Disk Units in an SVC Environment
Learn how to add additional disk units to an existing SVC configuration (including configurations using IBM FlashSystems or IBM Storwize storage devices)
Before you begin
These steps assume the user has experience configuring and managing an IBM® Spectrum Virtualize-based storage device and has a functioning configuration running.
Required PTF Group: These steps require the following PTF groups on all partitions in the PowerHA environment:
7.4: SF99666 Level 6
7.3: SF99876 Level 14
7.2: SF99776 Level 17
About this task
The Independent Auxiliary Storage Pool (IASP) volumes of your high availability configuration might require additional storage capacity. If your established SVC environment requires additional disk units for more capacity, complete the following procedure to add units to the IASP in an SVC environment.
Procedure
1. To add new disk units to the independent ASP, first create the new disk units (LUNs) on the source SVC storage controller.
2. Assign these new disk units on the source SVC storage controller to the source/production IBM i.
3. Initialize and format the new non-configured units on the source/production IBM i.
4. If the configuration contains either Metro Mirror or Global Mirror configure replication set up the target SVC storage controller and IBM i.
5. On the production system, add the new units to the ASP using SST.
6. Update the source copy description using the Change SVC Copy Description (CHGSVCCPYD
) command.
7. Update the target copy description using the Change SVC Copy Description (CHGSVCCPYD
) command.
8. Verify with the Display SVC Session (DSPSVCSSN
) command that replication is currently active for the session.
9. If the configuration contains FlashCopy, perform the following steps:
a. create the same number and size of disk units in the storage for the target copy of the FlashCopy and assign the disk units to the FlashCopy target node.
b. Update any FlashCopy target copy descriptions to contain new disk units for use in the FlashCopy environment. PowerHA will begin utilizing the new disk units during the next FlashCopy operation.
Results
The expanded storage in the environment on your IBM i partition is available for use.