Configuring the PowerHA Web Interface
The PowerHA Web Interface provides at-a-glance health information and allowing easy management of PowerHA operations from a web browser. 7.5 HA 5.2.2 7.4 HA 4.8.2
Software Requirements
The PowerHA Web Interface requires the following program temporary fixes (PTFs):
Release | PTF |
---|---|
7.5 PowerHA | SI81914 |
7.4 PowerHA | SI81913 |
Background
The PowerHA web interface is configured automatically with the following settings:
Run on non-secure HTTP port 2098
Automatically start when the *HTTP server is started
The web interface can be reached by going to the following URL in a web browser: http://<system-name>:2098
We recommend you configure the PowerHA web interface for secure HTTPS traffic. This ensures all information sent over the network is encrypted. See Enabling Secure HTTPS for the PowerHA Web Interface for additional information.
Web Interface Jobs
The PowerHA web interface introduces the following jobs into the system:
The QHTTPSVR subsystem will have up to 9 jobs named QHAWEBSVR that are responsible for providing the web interface. These jobs start and end when the PowerHA web server is started and ended.
The QSYSWRK subsystem will have the QHAWACNSVR job. PowerHA starts this job automatically when needed and typically keeps it running even when the web server is ended.
Additional Information
The following topics contain additional information on configuring the PowerHA Web Interfaces: